MC Building Dashboard

System Status: Optimal
Avg Temperature
22.1°C
0.5°C vs yesterday
CO2 Levels
510 ppm
8% vs last week
Server Heat Recovered
450 kW
+15% AI optimization
Energy Saved Today
320 kWh
Tracking to target

Temperature vs. CO2 Over 24h

AI Optimization Insights

MC 2066 (Lecture Hall): CO2 rising above 900ppm. Class in session.

Server Room (3rd Floor): Excess heat available from compute load.

Faculty Offices (5th Floor): Empty for 2 hours.

Critical Zone: Hottest Room

Server Room (3rd Floor)

29.0°C

Heat recovery system active. Diverting excess thermal energy to Floor 1 radiators.

Critical Zone: Highest Occupancy

Lecture Hall 2066

300/300

Room at maximum capacity. CO2 levels rising rapidly (1100ppm). AI preparing ventilation boost.

Current HVAC Load Distribution

MC Building 3D View

Drag to rotate. Click a floor to inspect.

Floor 6Dean & Admin
Floor 5Math Offices
Floor 4CS Offices
Floor 3Server Rooms
Floor 2Classrooms
Floor 1Main Lobby

Detailed Floor Plan

Floor 3 Selected
Room
Temp: 22°C
CO2: 400 ppm

Floor 3 Active Sensor Nodes

Node IDRoom TypeCurrent TempCO2 LevelStatus

MC Building HVAC Subsystems & AI Overrides

EquipmentZone ServedCurrent LoadAI RecommendationAction
Central Steam ExchangerWhole Building65%Stable
AHU - Lecture HallsFloor 1-340%Increase to 80% (High CO2)
Liquid Cooling LoopServer Rooms95%Divert heat to Corridor Radiators

Energy Consumption Breakdown

Server Heat Recycled (kWh)

Extended Historical Logs & AI Actions

TimestampZone LocationIssue DetectedAI Action TakenEst. Savings
Today, 10:45 AM3rd Floor ServersExcess Heat DetectedDiverted to 1st Floor Radiators+45 kWh
Today, 09:30 AMFaculty OfficesEmpty Zone (Calendar Sync)HVAC Setback applied+18 kWh
Yest, 14:15 PMLecture Hall 2066CO2 Spike (1200 ppm)Triggered VAV Box 100%N/A (Health)

Brookfield Challenge: Renewable Retrofits

Cost-effective sustainability through waste-energy harvesting.

Kinetic Energy Harvested
4.2 Wh
Powers 142 Nodes (100%)
Server Heat Recovered
450 kW
+15% vs yesterday
Est. Payback Period
3.2 Yrs
High ROI (Brookfield Spec)

Kinetic Tile Generation vs. Class Schedule

Battery-less IoT Network

Battery-less IoT

Replacing batteries in 500+ wireless sensors is a massive maintenance cost. By embedding ultra-cheap piezoelectric materials in the high-traffic Floor 1 lobby, we harvest just enough ambient kinetic energy to trickle-charge the mesh network.

Waste Heat as a Renewable

MC's 3rd Floor server farm generates massive heat. Instead of venting it, liquid-to-liquid exchangers capture this thermal load and pump it into the building's hydronic heating loop. A massive CapEx saver.

Digital Twin: HVAC Infrastructure

Floor 3: Live Ductwork & AI Damper Control.

Lecture Hall 3036 Mac Lab Server Room Linux Lab Grad Student Lounge HVAC Legend Cold Supply Air Hot Return Air AI VAV Damper

MC Building Network Status

142

Active Nodes in MC

  • Mesh Network Health: 99.9%
  • Average Latency: 8ms
  • Database Sync: Real-time

Deploy New Sensor Node

Power on your new Arduino node. The system will automatically detect it.